The TOP 200 telescopic optical probe is
typically used for the testing of displays and panel
graphics. It has been completely redesigned and is now based
on Pritchard style optics with an integrated alignment
camera. In comparison to the previous model (TOP 100), all
functions are now controlled via software, so that manual
operation is no longer required except for focus adjustment.
Light is guided from the TOP 200 to the
spectrometer via a multimode fiber. A patented mode mixer
from Instrument Systems ensures consistent transmission
through the fiber. This feature guarantees reproducible
measurement results, even when the fiber is physically
disturbed somewhere along its length.
Use of a Pritchard style optic means
that the viewing area around the spot can be observed and
monitored during the measurement. The image generated by the
alignment camera is automatically imported by the SpecWin
Pro software and saved together with the measurement
results.
Features:
- Pritchard optics with an aperture mirror
inclined at only 15° delivers perfectly
round and sharp image spots (products from
other manufacturers can exhibit ellipticity
and blur)
- flexible connection via optical fibers
incorporating a patented mode mixer ensures
reproducible results and very low
polarization sensitivity
- 6 different measurement spot sizes
selectable via software
- internal alignment camera with a wide
field of view
- smallest measurement spot 80 µm
- optional illumination of the test
object
Ordering Information:
|
Item Nr.
|
Item
Description
|
|
Basic
unit and fiber
|
|
TOP200-100
|
basic
telescope unit with adapter
for multimode fiber (w/o.
lens and fiber)
|
|
TOP200-101 |
multimode fiber (diameter 1
mm) with mode mixer and PLG
connector; 300-2200 nm
|
|
TOP200-102
|
UV
multimode fiber (diameter 1
mm) with mode mixer and PLG
connector; 190-1350 nm
|
|
Objective lenses and
close-up lenses
|
|
TOP100-308
|
fixed
focal length 28 mm; F/2.8;
370-1100 nm
|
|
TOP100-310
|
zoom
70-300 mm; F/4.2-5.8;
370-1100 nm
|
|
TOP100-311
|
fixed
focal length 60 mm; F/2.8;
370-1100 nm
|
|
TOP100-312
|
fixed
focal length 100 mm;F/2.8;
370-1100 nm
|
|
TOP100-313
|
fixed
focal length 200 mm; F/4.0;
370-1100 nm
|
|
TOP100-316
|
zoom
200-500 mm; F/5.0-6.3;
370-1100 nm
|
|
TOP100-319
|
fixed
focus 90 mm (HRL90); high
resolution; 370-1100 nm
|
|
TOP100-322
|
UV lens
105 mm; F/4.0; 200-800 nm
|
|
TOP100-350
|
close-up
lens; x4; 370-1100nm
|
|
TOP100-351
|
close-up
lens; x2; 370-1100nm
|
|
TOP100-360
|
UV
close-up lens; x4; 200-800
nm
|
|
TOP100-361
|
UV
close-up lens; x2; 200-800
nm
|
The following table provides an overview
of the spot sizes available with the 2 most important
lenses:
|
TOP100-311, 60 mm focal
length
|
HRL90
|
|
Working
Distance
|
180 mm
|
500 mm
|
1 m
|
230mm
|
|
Aperture
*
|
Spot
size [mm]
|
|
1
|
0.16
|
0.9
|
2.0
|
0.075
|
|
2
|
0.34
|
1.9
|
4.2
|
0.15
|
|
3
|
0.66
|
3.7
|
8.2
|
0.3
|
|
4
|
1.0
|
5.8
|
13
|
0.5
|
|
5
|
1.9
|
11
|
24
|
0.9
|
|
6
|
3.8
|
21
|
47
|
1.8
|
|
Camera
field of view [mm]
|
|
Width
|
7.0
|
40
|
93
|
3.5
|
|
Height
|
4.4
|
25
|
59
|
2.2
|
* Only apertures 1 to 4 can be used with
the standard multimode fiber. Apertures 5 and 6 can only be
used with the SPECTRO 320 in combination with a fiber